Designs of imaging systems.

I want to show here my ability to complete an optical design. The key features of design imaging systems are choosing a start design and its optimization using merit function until required optical performance is obtained. The start design should include enough lenses to achieve a balance of aberrations. The designs shown here were not sold, or permissions to their publications were obtained from my prior clients:    

  • The design of compact camera with narrow FOV for machine vision is shown in the link below. High-resolution image was obtained.

The compact camera with narrow FOV for machine vision.

  • The design of the compact camera with wide FOV is shown in the link below. Optics of the camera includes three aspherical plastic lenses and a single spherical glass lens.The design includes tolerance, ghost image, and thermal analyses.

  • The design of the artificial cornea for human eye is shown in the link below.

Design of artificial cornea for human eye.

  • The design of the micro-camera for endoscopy is shown in the link below.

The micro-camera for endoscopy.

  • The design of the imaging system of the fundus camera is shown in the link below. The camera has the range of adjustment from -10 Diopters to +10 Diopters.

Design of imaging system of fundus camera.

  • The design of the high-resolution camera for micro-scanning is shown in the link below.

The high-resolution camera for micro-scanning.

  • The design of VR glasses for correction of human vision is shown in the link below. The glasses have the range of adjustment from -10 Diopters to +10 Diopters.

VR glasses for correction of human vision.

  • The design of the imaging system of the device that can be used as a head-mounted fundus camera and retinal vessels analyzer is shown in the link below. The device has the range of adjustment from -10 Diopters to +10 Diopters.

The imaging system of the device that can be used as a head-mounted fundus camera and retinal vessels analyzer.

Some of my clients do not have a strong background in optical design. But, it is essential to know aberration theory for understanding the optical design process. I have not found the article that presents a short explanation of the theory. So, I wrote the article. It can be found in the link below.

A Short Explanation of Aberration Theory.


Designs of illuminating systems.

  • Illuminating system based on asymmetrical reflector and LEDs in Visible range and SWIR is shown in the link below.

Illuminating system based on asymmetrical reflector and LEDs.

  • Design of the illuminating system for the experiments with a porcine eye is shown in the link below.

Design of the illuminating system for the experiments with a porcine eye.

  • The design of the illuminating system of the device that can be used as a head-mounted fundus camera and retinal vessels analyzer is shown in the link below.

The illuminating system of the device that can be used as a head-mounted fundus camera and retinal vessels analyzer.